Capability statement

Built for big projects.

Large switchboards and motor control centres, designed, built and tested in Invercargill for consultants, main contractors and asset owners across New Zealand.

Long switchboard line-up with two air circuit breaker incomers in the CWS workshop, Invercargill
Our workshop, Invercargill
Since 1971Building switchboards in Invercargill
ISO 9001Quality management certified since 1995
25 staffDesign, build and test under one roof, including 3 in the drawing office and 3 apprentices
2,300 m²Factory floor
Switchboard systems

Three platforms, matched to the duty.

We build on three verified systems, so the board suits the fault level, the space and the people who will maintain it.

NZ made, design verified

Simotrol

NZ-made modular switchboard and MCC system, built in our Invercargill workshop.

  • 900 mm tiers (600 mm cell plus 300 mm cable duct) or 600 mm tiers, 2220 mm high on an 80 mm plinth
  • 450, 750 or 800 mm deep, single or double sided
  • Modular cells, 48 modules per tier, a standard cell size for every device
  • Group starter tiers for dense motor control, Form 4 cells for VSD supplies
  • Air circuit breaker incomers with CT metering and power monitoring
IEC 61439

Logstrup

Danish modular system, design verified to IEC 61439-1 and -2. CWS builds as the assembly manufacturer.

  • Main busbar up to 8,500 A (Icw 165 kA 1 s, Ipk 363 kA)
  • Rated to 690 V operational voltage
  • Largest CWS build: 4000 A, 100 kA MCC, 8 tiers (2026)
Accredited partner

Schneider Prisma

Schneider Electric Accredited Prisma Partner, building to Schneider’s verified Prisma design.

  • Genuine Schneider gear and parts throughout
  • Familiar to consultants and site maintenance teams
  • Largest CWS build: 2,000 A outdoor main switchboard, Form 4a, IP55 (2023)
Capacity in numbers

The size of board we build.

Our track record so far, with capacity to take on more.

Highest rating built4000 A, 100 kALogstrup MCC, 8 tiers, 2026
Longest board built24 tiers, 21.9 mSimotrol MCC, built in three stages
Longest in one build11 tiers, 9.9 mSimotrol MCC, 2012
Build capacityRoom for moreFloor space and people for further large projects. Ask about build slots.
Drawing office3EPLAN designers and drafters
Switchboard jobs a year450+Invoiced jobs, five-year average
Award to handover

How we deliver a large project.

One project manager

A dedicated project manager owns the job from award to handover and is your single point of contact for programme, changes and site.

Design locked early

EPLAN schematics and general arrangement drawings, checked against the quoted bill of materials before sign-off. Where required, 3D board models settle layout and enclosure weight early.

Long-lead gear ordered at award

Air circuit breakers and large MCCBs are ordered as soon as the design is signed off, so breaker lead times don’t set the programme.

Sections built in parallel

Tiers are built side by side and tested as each is finished, instead of waiting for the whole board.

Planned, staged delivery

Shipping splits and transport breaks are set at design and marked on the drawings, so sections arrive in the order site needs them.

Verified and documented

Routine verification to AS/NZS 61439 on every assembly. Test records, as-built drawings and O&M manuals at handover, plus site support to rejoin shipping splits.

Technology and digitisation

Digital from design to site.

Large boards are designed in EPLAN, modelled in 3D where the job needs it and can be fitted with monitoring, so you have a clear record before the build and live data after it.

EPLAN design

Our drawing office designs large boards in EPLAN, from schematics to panel layout, with parts data linked to the drawings.

3D board models

Where the application calls for it, a full 3D model of the board, and the switchroom if needed, settles layout, cable entry and weight before the build starts.

Power and condition monitoring

Power meters on incomers and feeders, with Schneider PowerLogic sensors for connection temperature, cubicle temperature and humidity, linked through an EcoStruxure Panel Server gateway.

Existing boards digitised

Older boards on the same site can be audited, redrawn and modelled in 3D, so the whole switchroom sits on one record. See switchboard audits and digitisation.

Reference projects

Large boards we have built.

ProjectBoardRatingYear
MCC with generator changeoverMeat processing plant, OtagoLogstrup MCC, 8 tiers, 5.19 m, Form 4a, ACB mains and generator incomers, arc flash protection. Designed, supplied, integrated and tested by CWS.4000 A, 100 kA2026
Engine room MCCMeat processing plant, SouthlandSimotrol MCC, 24 tiers, 21.94 m, built in three stages. Eight 2000 A bus sections with couplers, motor-operated incomers, PLC control.8 x 1000 A incomers2014 to 2017
Balance of plant MCCGas-fired power station, North IslandSimotrol MCC, 11 tiers, 9.94 m, three bus sections with couplers, motor-operated drawout ACBs.2 x 2500 A ACB, 65 kA 1 s2012
Battery storage switchboardRemote off-grid research stationSimotrol ACB section for a battery energy storage system, Form 4a, IK10.4000 A ACB, 63 kA 1 s2024
Main switchboardCold storage facility, North IslandSimotrol MSB, double sided, 7 tiers, 6.36 m, Form 4a.2 x 2500 A ACB, 50 kA 1 s2024

Preferred supplier tomajor New Zealand dairy and meat processors and heavy industry.

More completed work in our case studies.

Pre-qualification

Ready for your tender.

Ask us for current certificates, insurance details, our health and safety system and references for your tender or contractor onboarding.

  • ISO 9001Quality management, certified since 1995
  • Schneider ElectricAccredited Prisma Partner
  • TōtikaContractor prequalification
  • SiteWise Green2026/27 prequalification
  • AvettaContractor registration
  • Master ElectriciansIndustry membership
  • SimotrolDesign verified to AS/NZS 61439
Built in New Zealand

Why a local builder on a big job.

No sea freight from Europe

Shorter lead times and less risk of transit damage than imported switchgear.

Built for NZ from day one

MEN earthing arrangement, NZ cable sizes and NZ labelling, not modified after arrival.

Late changes handled here

Design changes are made in Invercargill by the team that built the board, not shipped back overseas.

Service for the life of the asset

Spares, maintenance and modifications from the people who built it.

Compliance

CWS is the assembly manufacturer for every board we build and carries out routine verification to AS/NZS 61439 on each one. Design verification records for each system are available on request.

Large project coming up?

Bring us in at design stage.

Early involvement locks in breaker lead times, shipping splits and a realistic programme. Come and see a large board being built in our factory.

IP Geolocation by DB-IP · CC BY 4.0