33 Clyde Street, Invercargill 9810, NZ
Mon-Fri 08:00 AM - 05:00 PM

Resources & Downloads

Download LV switchboard certifications, IEC 61439 test reports, and technical documentation for Clive Wilson Switchboards’ main switchboards and MCC systems used across industrial and infrastructure projects in New Zealand.

Capability Statements

2 documents

Company Profile - Logstrup

Full capability statement covering our services, certifications, OEM partnerships, and project experience.

PDF • 2026 Download PDF →

Company Profile - Simotrol

Capability statement featuring our Simotrol MCC and switchboard manufacturing capabilities.

PDF • 2026 Download PDF →

Certifications

4 documents

Prisma P - IEC 61439 Certificate

IEC 61439 type-tested certification for Schneider Electric Prisma P low-voltage switchboard assemblies.

PDF • Schneider Electric Download PDF →

Prisma G - IEC 61439 Certificate

IEC 61439 type-tested certification for Schneider Electric Prisma G switchgear and controlgear assemblies.

PDF • Schneider Electric Download PDF →

Quantum 800A - IEC 61439 Test Certificates

TUV Rheinland type-tested certifications for the Quantum 800A switchboard, short-circuit and temperature rise tests.

PDF • TUV Rheinland

Quantum Compliance

Compliance documentation for Quantum switchgear assemblies against AS/NZS 61439-2 requirements.

PDF • Rev C Download PDF →

Technical Documents

3 documents

Switchboard Maintenance Checklist

Printable routine maintenance checklist for LV main switchboards, MCCs and distribution boards - covering annual, quarterly and monthly tasks for facility engineers and electrical contractors.

PDF Download PDF →

MTZ Air Circuit Breaker Maintenance Guide

Maintenance procedures and service intervals for Schneider Electric MTZ series air circuit breakers.

PDF Download PDF →

Prisma G IP55 Catalogue

Product catalogue for the Schneider Electric Prisma G IP55 switchboard enclosure range.

PDF Download PDF →

Online Tools

2 tools

NZ Transformer Fault Current Calculator

Calculate the prospective short circuit current at the LV terminals of a three-phase distribution transformer. Enter kVA rating, voltage and nameplate impedance to get fault current values for switchboard fault level compliance.

Interactive Tool · Free Open Calculator

IP Rating & Material Selector

Answer 6 questions about your install environment and get an IP rating (AS/NZS 60529) and enclosure material recommendation for your NZ LV switchboard. Covers coastal, geothermal, wash-down, and dusty conditions.

Interactive Tool · Free Use the tool